Bacharach Flue-Gas Sample Conditioning System Dokumentacja Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 28
ECA 450 Operation
Instruction 0024-9400
25
2.13 Importing Saved Data Into a Spreadsheet
A text file that was created as described in either Section 2.11 Downloading
Data to a Personal Computer, or Section 2.12 Data Logging can be imported
into spreadsheet programs that are capable of importing comma-delimited
files. Note that each data record consists of 31 fields, some of which may be
blank for different tests and analyzer configurations.
TABLE 1. COMMA-DELIMITED FIELDS
Field
Data Name or Value
Label in Column
Heading
1
Test ID Line 1 (up to 20 characters)
TESTID1
2
Test ID Line 2 (up to 20 characters)
TESTID2
3
Test ID Line 3 (up to 20 characters)
TESTID3
4
Fuel Name
FUEL
5
Temperature Unit of Measure used in fields 14 &15
TEMP UNIT
6
Pressure Unit of Measure used in field 31
PRESS UNIT
7
Pollution Unit of Measure used in fields 11, 18 thru 21,
24, 26, 27, 28 & 30
POLL UNIT
8
Date of Test
DATE
9
Time of Test
TIME
10
O
2
Concentration in %
O2
11
CO Concentration
CO
12
Combustion Efficiency in %
EFF
13
CO
2
Concentration in %
CO2
14
Stack Temperature
TSTACK
15
Primary Air Temperature Measurement Source
TAIR SOURCE
16
Primary Air Temperature
TAIR
17
Excess Air in %
EA
18
NO Concentration
NO
19
NO
2
Concentration
NO2
20
NOx Concentration
NOX
21
SO
2
Concentration
SO2
22
Hydrocarbon (combustibles) Level in % Gas
HC
23
O
2
Reference for CO in Field 24
CO(O2R)
24
CO Concentration Referenced to O
2
CO(O2)
25
O
2
Reference for NO, NO
2
and NOx in Fields 26, 27 & 28
NOX(O2R)
26
NO Concentration Referenced to O
2
NO(O2)
27
NO
2
Concentration Referenced to O
2
NO2(O2)
28
NOx Concentration Referenced to O
2
NOX(O2)
29
O
2
Reference for SO
2
in Field 30
SO2(O2R)
30
SO
2
Concentration Referenced to O
2
SO2(O2)
31
Pressure (Draft) Measurement
PRESSURE
Przeglądanie stron 28